Sold

2001 FULTON COIL DESIGN THERMAL FLUID HEATER FT-0240C

Chillers, Boilers, and HVAC
Manufacturer:
FULTON
Model:
FT-0240C
Stock #:
BC0413-2423E
<font rwr='1' size='4' style='font-family:Arial'><div style=""><font face="Arial"><span style="font-size: 18.6667px;"><b>2001 FULTON COIL DESIGN THERMAL FLUID HEATER FT-0240C</b></span></font></div><div style="font-family: &quot;Times New Roman&quot;; font-size: medium;"><font face="Arial"><span style="font-size: 18.6667px;"><b><br></b></span></font></div><div style="font-family: Arial; font-size: large;"><font face="Arial"><b><span style="font-size: 14pt;">MANUFACTUER:&nbsp;</span></b></font><b style="font-size: 18.6667px;">FULTON</b></div><table align="center" style="font-family: &quot;Times New Roman&quot;; font-size: 14pt; border-spacing: 0px; width: 1381px;"><tbody><tr><td><div id="ds_div"><table align="center" style="border-spacing: 0px; width: 1379px;"><tbody><tr><td><div id="ds_div"><br></div></td></tr></tbody></table></div></td></tr></tbody></table><div style="font-family: Arial; font-size: large;"><font face="Arial" style="font-size: 14pt;"><b>MODEL</b></font><b style="font-size: 14pt;">:&nbsp;</b><b style="font-size: 18.6667px;">FT-0240C</b></div><div style="font-family: Arial; font-size: large;"><b style="font-size: 18.6667px;"><br></b></div><div style="font-family: Arial; font-size: large;"><font face="Arial"><b><span style="font-size: 14pt;">CONDITION: USED/GOOD CONDITION</span></b></font></div><div style="font-family: Arial; font-size: large;"><font face="Arial"><b><span style="font-size: 14pt;"><br></span></b></font></div><div style="font-family: Arial; font-size: 14pt;"><b style="font-size: 14pt;">BC0413-2423E</b></div><div style="font-family: Arial; font-size: 14pt;"><b style="font-size: 14pt;"><br></b></div><div style="font-family: Arial; font-size: 14pt;"><b style="font-size: 14pt;">SPECIFICATIONS:</b></div><div style="font-family: Arial; font-size: 14pt;"><ul><li><b style="font-size: 14pt;">OVERALL WIDTH: 50.1 INCHES</b></li><li><b style="font-size: 14pt;">OVERALL DEPTH: 66.6 INCHES</b></li><li><b style="font-size: 14pt;">OVERALL HEIGHT: 89.7 INCHES</b></li><li><b style="font-size: 14pt;">HEATER HEIGHT: 65.1 INCHES</b></li><li><b style="font-size: 14pt;">HEIGHT TO SAFETY VALVE OUTLET: 82.9 INCHES</b></li><li><b style="font-size: 14pt;">HEATER OUTLET/INLET HEIGHT: 71.9 INCHES</b></li><li><b style="font-size: 14pt;">HEIGHT TO CENTER OF FLUE: 54.1 INCHES</b></li><li><b style="font-size: 14pt;">FLUE DIAMETER: 12 INCHES</b></li><li><b style="font-size: 14pt;">THERMAL FLUID INLET: 2.5 INCHES</b></li><li><b style="font-size: 14pt;">THERMAL FLUID OUTLET: 2.5 INCHES</b></li><li><b style="font-size: 14pt;">SAFETY RELIEF VALVE OUTLET: 2 INCHES</b></li><li><b style="font-size: 14pt;">RECOMMENDED STACK DIAMETER: 14 INCHES</b></li><li><b style="font-size: 14pt;">HEAT OUTPUT: 2,400,000 BTU/HR. OR 703 kW</b></li><li><b style="font-size: 14pt;">FUEL INPUT: 21.4 No. 2 OIL (U.S.) GPH</b></li><li><b style="font-size: 14pt;">GAS PRESSURE REQUIRED: 14 IN W.C. OR 3.48 kPa</b></li><li><b style="font-size: 14pt;">RECOMMENDED CIRCULATION RATE: 150 GPM</b></li><li><b style="font-size: 14pt;">PRESSURE DROP ACROSS HEATER AT RECOMMENDED CIRCULATION RATE: 30 PSID OR 207 kPa</b></li><li><b style="font-size: 14pt;">BURNER MOTOR: 3 HP OR 2.2 kW</b></li><li><b style="font-size: 14pt;">CIRCULATING PUMP MOTOR: 15 HP OR 11.2 kW</b></li><li><b style="font-size: 14pt;">HEATER FLUID CONTENT: 31 GALLONS</b></li><li><b style="font-size: 14pt;">HEATER DRY WEIGHT: 3,400 LBS.</b></li></ul></div></font>
Loading...